Series PSCII™

Products » Residential Boilers » Series PSCII™

The Series PSCII™ boiler is a direct vent, sealed combustion boiler for hot water heating systems. Fully packaged and ready to install, the Series PSCII™ residential, gas-fired boiler is designed for through-the-wall direct venting. Through the roof venting is an option. Using outside air for combustion, direct venting is ideal for applications where the chimney is inadequate or unavailable. A unique sidewall thimble with screened vent termination is provided and requires only one hole in the outside wall. Available with standard intermittent ignition, the Series PSCII™ boiler is available as natural or LP gas fired. Honeywell operating controls and a Taco circulator are offered as standard equipment. The Series PSCII™ boiler is available in 4 sizes (3-6 sections), with inputs from 65.0 to 150.0 MBH. Cast iron sections are factory tested and assembled with steel push nipples.

Type: Residential
Construction: Cast Iron
Fuel: Gas-Fired (Natural or LP)
Input: 65 to 150 MBH
Output: 56 to 128 MBH
Venting: Sealed Combustion, Direct Vent
Trim: Water
Ignition: Fan Assisted Intermittent

 

  • Packaged Residential Hot Water Boilers
  • Natural or LP Gas
  • Sealed Combustion, Direct Vent
  • Intermittent Ignition
  • Unique Wall Thimble

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

Series PSC II™ Water Content, gal
Model Number Input, MBH Heating Capacity3, MBH Net I=B=R Ratings Water1,2, MBH Intermittent Ignition AFUE3, %
PSC II-03 65 56 49 86.0 4.72
PSC II-04 90 77 67 85.0 6.00
PSC II-05 120 102 89 85.0 7.28
PSC II-06 150 128 111 85.1 8.56

1 Net I=B=R water ratings based on an allowance of 1.15.

2 Consult factory before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.

3 Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) ratings are based on U.S. Government test. Before purchasing this appliance, read important information about its estimated annual energy consumption or energy efficiency rating that is available from your retailer.

Don't see the information you need? See the "Related Documents" tab for product resource downloads.

Series PSCII™ Boiler Dimensions

Boiler Model Number Jacket Width "A"
PSC -03 12 1/2" 318 mm
PSC -04 15 7/8" 403 mm
PSC -05 19 1/4" 489 mm
PSC -06 22 5/8" 575 mm

Don't see the information you need? See the "Related Documents" tab for product resource downloads.